Some aspects of metallurgical assessment of boiler tubes

Some aspects of metallurgical assessment of boiler tubes—Basic principles and case studies - Mate VIP VIP 100w VIP

Get a Quote

A Review on Boiler Tube Assessment in Power Plant using

2018-6-13 · overheating major damage mechanism contribute in boiler tube failures. Scheduled maintenance of boiler tubes include ultrasonic measurement of wall thickness and find defective, it involves cutting tube section and performing metallurgical analysis for losses of original strength due to overheating of tubes.

Get a Quote

Boiler Tube Scale Deposit Measurement Program

2016-4-19 · Boiler Tube Scale Deposit Measurement Program Valmet Inc., Energy and Environmental (ENE) Boiler tubes are prepared by cleaning an area of 1x1 inch Inspection Technique Wave form measurement Scale thickness measurement is based on reflection of longitudinal ultrasonic waves from different interfaces. Sound is reflected from both metal

Get a Quote

EMAT thickness measurement for tubes in coal-fired …

EMAT thickness measurement for tubes in coal-fired boilers EMAT thickness measurement for tubes in coal-fired boilers Bergander, Mark J. 2003-03-01 00:00:00 Boilers, the most troublesome components of electric-power generation plants, cost the US utility industry over $5 billion per year in unscheduled shutdowns, repairs and power replacements.

Get a Quote

Measurement of wall thickness of steam boiler tubes …

Measurement of wall thickness of steam boiler tubes with EMAT transducers. The presence of this oxide layer on the outside of tubes can interfere with ultrasonic wall thickness measurements using common dual element transducers, both because it can have a very rough surface that prevents proper sound coupling, and because the oxide

Get a Quote

Remaining life assessment for boiler tubes affected by

Authors have undertaken a systematic research with the major objective to correlate the results of combined nondestructive testing (NDT) with condition assessment of boiler tubes. The evaluation included non-contact wall thickness measurement with EMAT technology plus internal oxide layer measurement with specialized ultrasonics.

Get a Quote

Measuring Oxide Scale Thickness on The Inner Surface of …

2010-3-13 · of scale increase rapidly [2]. Periodic measurement of scale thickness allows a plant operator to estimate remaining tube service life and to replace tubes that are approaching the failure point. Ultrasonic pulse/echo thickness measurement techniques have been used for internal oxide scale measurement for many years.

Get a Quote

Boiler Tube Scale Deposit Measurement Program

2016-7-13 · Boiler Tube Scale Deposit Measurement Equipment Hardware and Software System: Boiler tubes are prepared by cleaning an area of 1x1 inch surface without removing any base metal. Inspection Technique Wave form measurement Scale thickness measurement is based on reflection of longitudinal ultrasonic waves from different interfaces.

Get a Quote

EMAT thickness measurement for tubes in coal-fired …

The non-destructive testing technique is an important tool for predicting the life of boiler tubes. A standard ultrasonic technique is used for measuring their wall thicknesses and determining the degree of corrosion. Such a test requires clean, rust-free surface and all tubes must be sandblasted prior to the inspection.

Get a Quote

Boiler tube inspection with EMAT - Innerspec …

The temate ® TG-IS(B) is designed for detecting and measuring wall loss, hydrogen damage and caustic gauging in boiler tubes. The temate TG-IS(B) is available for purchase or rental from Innerspec Technologies. Features. Non-contact EMAT technique. Permits inspection of boilers instead of spot checking at up to 15cm/s of scanning speed.

Get a Quote

EMAT thickness measurement for tubes in coal-fired …

EMAT thickness measurement for tubes in coal-fired boilers tool for predicting the life of boiler tubes. A standard ultrasonic technique is used for measuring their wall thicknesses and

Get a Quote

Boiler tube inspection with EMAT - Innerspec …

The temate ® TG-IS(B) is designed for detecting and measuring wall loss, hydrogen damage and caustic gauging in boiler tubes. The temate TG-IS(B) is available for purchase or rental from Innerspec Technologies. Features. Non-contact EMAT technique. Permits inspection of boilers instead of spot checking at up to 15cm/s of scanning speed.

Get a Quote

US4353257A - Nondestructive system for testing the

The present invention relates to a system for the nondestructive testing of the thickness of boiler tubes. The system comprises a probe assembly which includes a mounting unit for mounting the assembly in a mud or water drum of a boiler at the location of a boiler tube to be tested. The probe assembly is comprised of an ultrasonic transducer for transmitting and receiving ultrasonic signals.

Get a Quote

Creep-Rupture Assessment of Superheater Tubes Using

2006-3-7 · Creep-Rupture Assessment of Superheater Tubes Using Nondestructive Oxide Thickness Measurements BR-1697 Abstract Steam-carrying superheater and reheater tubes in fos-sil-fired boilers operating at temperatures above 900F (482C) are subject to failure by creep-rupture. These tubes form an internal oxide layer that inhibits heat transfer

Get a Quote

70024 Boiler tube oxide scale thickness measurement

2018-4-18 · and Oxide on Thick Wall Boiler Tubes • Use "compare mode" to view set-up standard vs. actual measurement • High display resolution and range allows for clear signal interpretation and resolving the measurement 70024 Boiler tube oxide scale thickness measurement

Get a Quote

Boiler tube scale deposit measurement - valmet.com

A well planned and executed boiler chemistry control program is essential to prevent tube failure. Valmet's Boiler Tube Scale Deposit Measurement Program is an effective inspection service that will enhance your program and help us better understand the deposition within your boiler. Nondestructive measurement of scale deposit

Get a Quote

NON-DESTRUCTIVE METHOD FOR INNER SCALE …

2018-4-18 · OF BOILER TUBES Vinícius P. R. Figueiredo1, Vitor E. Moreira1, Oscar I. Hassegawa1, Ronaldo F. Faria1 1 CBC Heavy Industries S/A, Brazil ABSTRACT Boiler tube failures may cause forced shutdowns on facilities, and the thickness of the oxide deposited on the wall tubes inner surface, is the main cause of overheating damages.

Get a Quote

: Thickness measurement of INCONEL ® coatings

Thickness measurement of INCONEL ® coatings on waste heat recovery boilers Known for their resistance to oxidation and corrosion, Inconel alloys are often used in extreme environments subject to high heat and pressure.

Get a Quote

Thickness Measurement Technology using Cable-less …

2016-12-27 · Mitsubishi Heavy Industries Technical Review Vol. 53 No. 4 (December 2016) 64 the sensor of the cable-less inner UT system is 35 mm when the tube inner diameter is 30 mm, with a minimum tube inner diameter of 25 mm. Due to development of the small sensor, almost all of our boiler heat exchanger tubes can be measured.

Get a Quote

Boiler Tube Scale Deposit Measurement Program

2015-11-9 · Boiler Tube Scale Deposit Measurement Equipment Hardware and Software System: Boiler tubes are prepared by cleaning an area of 1x1 inch surface without removing any base metal. Inspection Technique Wave form measurement Scale thickness measurement is based on reflection of longitudinal ultrasonic waves from different interfaces.

Get a Quote

Related Information